Stego FPI/FPO 018 | UP TO 97 M³/H (124 X 124 MM) Filter Fan Plus

Stego FPI/FPO 018 | UP TO 97 M³/H (124 X 124 MM) Filter Fan Plus

الكود: FPI/FPO 018 | UP TO 97 M³/H (124 X 124 MM)
العلامة التجارية: Stego
Axial fan, ball bearing service life L10 at +40 °C (+104 °F): min. 37,000 h
fan body aluminium, rotor metal
Connection 2 stranded wires, 300 mm
Casing, hood, flaps plastic according to UL94 V-0, light grey;
UV light resistant according to UL746C (f1)
Enclosure cut-out 124 x 124+1 mm
Mounting frame 4 built-in ratchet braces for mounting
(6 notches for wall thickness 1-4 mm).
Additional use of screws possible if needed1.
Filter mat ISO coarse 55 % acc. to ISO 16890 (G3),
initial gravimetric arrestance 57 %
Filter material synthetic fibre with progressive construction, temperature
resistant to +100°C, self-extinguishing class F1,
moisture resistant to 100% RH, reusable
Operating/Storage temperature -40 to +70 °C (-40 to +158 °F)
Operating/Storage humidity max. 90 % RH (non-condensing)
Protection type/Protection class IP54 / I (earthed)
Environmental rating UL/NEMA UL TYPE 12 / NEMA 12
Approvals VDE, UL File No. E234324, EAC
Note other voltages on request

1 Drilling marks for screw mounting are indicated on mounting frame.

AIRFLOW DIRECTION "IN": FILTER FAN FPI 018

Art. No. Operating voltage Air volume,
free flow
Air volume
with exit filter
Current
consumption
(50/60 Hz)
Power
consumption
Average noise level
(DIN EN ISO 4871)
Depth in
enclosure
Weight
(approx.)
Filter mat
01871.0-30 AC 230 V, 50/60 Hz 52 m³/h 42 m³/h 120 mA 19 W 49 dB (A) 66 mm 0.8 kg G3
01871.9-30 AC 115 V, 50/60 Hz 62 m³/h 51 m³/h 230 mA 18 W 53 dB (A) 66 mm 0.8 kg G3

AIRFLOW DIRECTION "IN": EXIT FILTER FPI 118

Art. No. Depth in enclosure Weight (approx.) Air outlet
11871.0-00 35 mm 0.3 kg air-flap outlet technology

AIRFLOW DIRECTION "OUT": FILTER FAN FPO 018

Art. No. Operating
voltage
Air volume,
free flow
Air volume
with intake filter
Current
consumption
(50/60 Hz)
Power
consumption
Average noise level
(DIN EN ISO 4871)
Depth in
enclosure
Weight
(approx.)
Air outlet
01881.0-00 AC 230 V, 50/60 Hz 97 m³/h 47 m³/h 120 mA 19 W 49 dB (A) 79 mm 0.9 kg air-flaps
01881.9-00 AC 115 V, 50/60 Hz 117 m³/h 58 m³/h 230 mA 18 W 52 dB (A) 79 mm 0.9 kg air-flaps

AIRFLOW DIRECTION "OUT": INTAKE FILTER FPO 118

Art. No. Depth in enclosure Weight (approx.) Filter mat
11881.0-30 22 mm 0.2 kg ISO coarse 55 % acc. to ISO 16890 (G3), initial gravimetric arrestance 57 %

FILTER MAT FM 086

Filter class 118 x 118 mm Initial gravimetric arrestance 1 packing unit
ISO coarse 55 % acc. to ISO 16890 (G3) Art. No. 08634.0-00 57 % 5 pieces

TECHNICAL DRAWINGS

FPI 018/FPI 118
FPO 018/FPO 118

Stego ورقات البيانات

البلد واللغة اسم الملف رابط التحميل
United States (English) stego-EN_54310.pdf تحميل
Deutschland (Deutsch) stego-DE_71351.pdf تحميل
Italy (Italiano) stego-IT_60429.pdf تحميل

طلب عرض سعر