Code: 600-260-4AD01
Marke: Helmholz
| General information |
|---|
| Order number | 600-260-4AD01 |
|---|
| Article name | AO 4x I, 0/4 ... 20 mA, 12 bit |
|---|
| Scope of delivery | AO 4x I, 0/4 ... 20 mA, 12 bit |
|---|
| Dimensions (DxWxH) | 110 x 14 x 73 mm |
|---|
| Weight | Approx. 70 g |
|---|
| Number of outputs | 4 |
|---|
| Output ranges | 0 … 20 mA, 4 … 20 mA |
|---|
| Electrical isolation |
|---|
| from the backplane bus | Yes |
|---|
| Between the channels | No |
|---|
| Current draw |
|---|
| External | Max. 100 mA |
|---|
| Internal | Max. 26 mA |
|---|
| Power dissipation | Max. 3 W |
|---|
| Connection for actuators | 2-wire connection |
|---|
| Load resistance | Max. 600 ohms |
|---|
| Inductive load | Max. 100 mH |
|---|
| No-load voltage | max. 18 V |
|---|
| Measurement resolution | 12 bit |
|---|
| Values presentation | SIMATIC* S7 | SIMATIC* S5 | INT16 |
|---|
| Refresh time | 0.2 ms |
|---|
| Settling time | 0.2 ms for resistive loads, 2.2 ms for capacitive loads, 0.5 ms for inductive loads (<=1 mH), 3.3 ms for inductive loads (<=3.3 mH) |
|---|
| Diagnoses | External reference voltage missing (L+), wire break, parameter assignment error |
|---|
| Process alarms | Upper and lower limit per channel |
|---|
| Error limits |
|---|
| Operational error limit in the entire temperature range | ±0.5 % relative to the nominal range |
|---|
| Basic error limit at 25 °C | ±0.3 % relative to the nominal range |
|---|
| Temperature error | ±0.005 %/K relative to the nominal range |
|---|
| Linearity error | ±0.05 %/K relative to the nominal range |
|---|
| Repeating accuracy in steady state at 25 °C | ±0.05 %/K relative to the nominal range |
|---|
| Parameter configuration length | 13 bytes |
|---|
| General error indicator | Red LED |
|---|
| Hot-swap capable | Yes |
|---|
| Ambient conditions |
|---|
| Ambient temperature | 0 °C … +60 °C |
|---|
| Transport and storage temperature | -20 °C … +80 °C |
|---|
| Relative air humidity | 95 % r H without condensation |
|---|
| Protection rating | IP 20 |
|---|
| Certifications | CE, UL |
|---|
| UL |
|---|
| Surrounding Air Temperature | 0 °C … +60°C |
|---|
| Pollution degree | 2 |
|---|
| CE |
|---|
| Noise immunity | DIN EN 61000-6-2 “EMC Immunity” |
|---|
| Interference emission | DIN EN 61000-6-4 “EMC Emission” |
|---|
| Vibration and shock resistance | DIN EN 60068-2-6:2008 „Vibration“, DIN EN 60068-2-27:2010 „Shock" |
|---|
| RoHS | Yes |
|---|
| REACH | Yes |
|---|