Code: SR3E
Marke: Zander Aachen
SR3E |
|
Safety function |
Emergency stop monitoring for elevators |
Safety certified according to |
EN 81-20:2014; EN 81-50:2014 |
Also safety certified according to |
EN ISO 13849-1:2015; EN 62061:2005 + A2:2015; IEC 61508 Part 1-2 and 4-7:2010 |
Approvals |
CE, TUV |
Supply voltage |
DC 24 V +/- 10% |
Number of safe relay contacts |
3 |
Max. switching capability of safe relay contacts |
8 A / 250 VAC resistive load |
Number of auxiliary relay contacts |
1 |
Number of non time-delayed safe contacts |
3 |
Number of time-delayed safe contacts |
- |
Starting behavior |
Automatic start or manual, monitored start |
PL; Cat.; SILCL (EN ISO 13849-1:2015; EN 62061:2005 + A2:2015; IEC 61508 Part 1-2 and 4-7:2010) |
PL e; Cat. 4; SILCL 3 |
Width |
22.5 mm |
Order No. fixed screw terminals |
472292 |
Order No. plug-in screw terminals |
474292 |
Order No. push-in twin spring connector |
475292 |
Order No. Spacer for a defined minimum distance between two safety relays (see derating) |
472596 |
Fordern Sie ein Angebot an