Code: ZStop LE
Marke: Zander Aachen
| ZStop-LE |
|
| Corresponds to the standards |
EN ISO 13850; IEC 60947-5-5; UL508 |
| Approvals |
UL |
| Safety Contact Type |
IEC 60947-5-1 Douple Break Type Zb |
| Contact material |
silver |
| Termination |
Clamp up to 2.5 sq. mm conductors |
| Rating |
Uitlization Category: AC15 |
| Operational Rating |
AC15 A300 240V. 3A/120V 6A AC |
| Thermal Current (Ith) |
10A |
| Rated Insulation Voltage (Ui) |
500V |
| Withstand Voltage |
2500V |
| Short Circuit Overload Protection |
Fuse Exernally 10A (FF) |
| Body material |
Plastic (ZStop-S), Stainless steel 316 (ZStop SE, LE,LEL). |
| Protection |
IP69K Stainless Steel (NEMA 6), IP67 Plastic |
| Temperature range |
-25°C to +80°C |
| Mechanical Reliability B10d |
1.5 x 10 (superscript 6) operations at 100mA load |
| ISO 13849-1 |
up to PLe depending on system architecture |
| EN 62061 |
up to SIL3 depending on system architecture |
| EN 62061 |
up to SIL3 depending on system architecture |
| Order No. ZStop-LE (Stainless Steel) |
941602 |