Code: SRTC
Brand: Zander Aachen
| SRTC |
|
| Safety function |
In combination wit SR-basic relay: emergency stop monitoring, safety guard monitoring, light grids monitoring |
| Certified according to |
EN 60204-1; EN ISO 13849-1 ; EN 62061 |
| Approvals |
CE, TUV, UL |
| Supply voltage |
AC/DC 24 V / AC 115 V / AC 230 V |
| Number of safe relay contacts |
3 |
| Max. switching capability of safe relay contacts |
6 A / 250 VAC resistive load |
| Number of auxiliary relay contacts |
1 (Feedback Loop - Basic Modul) |
| Number of non time-delayed contacts |
- |
| Number of time-delayed contacts |
3 |
| Adjustable time delay |
1 - 30 s |
| Starting behavior |
Switches on and of with basic relay |
| PL; Cat.; SILCL (EN ISO 13849-1; EN/IEC 62061) |
PL d; Kat. 3; SILCL 2 |
| Width |
22.5 mm |
| Order No. fixed screw terminals |
472192 (24 V) / 472191 (115 V) / 472190 (230 V) |
| Order No. plug-in screw terminals |
474192 (24 V) / 474191 (115 V) / 474190 (230 V) |
| Order No. push-in twin spring connector |
475192 (24 V) / 475191 (115 V) / 475190 (230 V) |
| Order No. EKLS4, set of plug-in screw terminals |
472592 |
| Order No. EKLT4; set of push-in twin spring connector |
472595 |
Request a Quote