General information |
---|
| Order number | 600-250-7BH21 |
---|
| Article name | AI 8 x I, 0/4-20 mA, ±20 mA, Iso., 16-bit |
---|
| Scope of delivery | AI 8 x I, 0/4-20 mA, ±20 mA, Iso., 16-bit |
---|
| Dimensions (DxWxH) | 110 x 25 x 73 mm |
---|
| Weight | Approx. 110 g |
---|
Number of inputs | 8 |
---|
Electrical isolation |
---|
| from the backplane bus | Yes |
---|
| Between the channels | Yes |
---|
Current draw |
---|
| External | Not needed |
---|
| Internal | Max. 140 mA |
---|
Power dissipation | Max. 1 W |
---|
Measuring ranges / load resistance | 0 ... 20 mA / 50 ohms, 4 ... 20 mA / 50 ohms, ±20 mA / 50 ohms |
---|
Measuring method | Integration |
---|
Measurement resolution | 15 bits + sign |
---|
Values presentation | SIMATIC* S7 | SIMATIC* S5 | INT16 |
---|
Interference frequency suppression | None | 10 Hz | 50 Hz | 60 Hz | 400 Hz |
---|
Refresh rate / conversion rate | The conversion time will depend on the interference frequency suppression: None: 2 ms 400 Hz: 8 ms 60 Hz: 51 ms 50 Hz: 60 ms 10 Hz: 160 ms |
---|
Diagnoses | Upper measuring range limit exceeded (overflow), Lower measuring range limit fallen below (underflow), Wire break (for 4 ... 20 mA only), Parameter assignment error |
---|
Process alarms | Upper and lower limit per channel |
---|
Error limits |
---|
| Operational error limit in the entire temperature range | ±0.2 % relative to the nominal range |
---|
| Basic error limit at 25 °C | ±0.1 % relative to the nominal range |
---|
| Temperature error | ±0.005 %/K relative to the nominal range |
---|
| Linearity error | ±0.05 %/K relative to the nominal range |
---|
| Repeating accuracy in steady state at 25 °C | ±0.05 %/K relative to the nominal range |
---|
Parameter configuration length | 44 Bytes |
---|
General error indicator | Red LED |
---|
Hot-swap capable | Yes |
---|
Ambient conditions |
---|
| Ambient temperature | 0 °C … +60 °C |
---|
| Transport and storage temperature | -20 °C … +80 °C |
---|
| Relative air humidity | 95 % r H without condensation |
---|
| Protection rating | IP 20 |
---|
| Certifications | CE, UL |
---|
UL |
---|
| Surrounding Air Temperature | 0 °C … +60°C |
---|
| Pollution degree | 2 |
---|
CE |
---|
| Noise immunity | DIN EN 61000-6-2 “EMC Immunity” |
---|
| Interference emission | DIN EN 61000-6-4 “EMC Emission” |
---|
| Vibration and shock resistance | DIN EN 60068-2-6:2008 „Vibration“, DIN EN 60068-2-27:2010 „Shock" |
---|
| RoHS | Yes |
---|
| REACH | Yes |
---|