Zander Aachen TB-I14O3 up to 990 s Compact Safety Controller

Zander Aachen TB-I14O3 up to 990 s Compact Safety Controller

Code: TB-I14O3 up to 990 s
Marque: Zander Aachen

TALOS® has incorporated the desired functionality in a flexible manner. The desired configuration can be selected and individual functions such as delay times can be parametrized directly on the device via the menu in an easy and quick manner. This implies: no expensive programming operations, quick and easy operation and commissioning without any other ancillary equipment such as PC. A built-in monitoring device avoids long trouble-shooting hours and downtime.

The 14 safety inputs can be variably linked, with or without time functions, with 3 safety and 6 auxiliary outputs by means of logic.

TALOS® TB-I14O3 - up to 990 s
Safety functionEmergency stop monitoring, safety guard monitoring, light grids monitoring, for furnaces in continuous operation, stop category 0/1
Certified according toEN ISO 13849-1:2015, EN 50156-1:2015, EN62061:2005 + AC: 2010 + A1:2013 + A2:2015, IEC 61508 Parts 1-7:2010, IEC 61511-1:2016, EN 746-2:2010
ApprovalsCE, TUV
Supply voltageUB: DC 24 V (+/- 15 %)
Power consumption3,8 W (all inputs activated / no load operation)
Number of safe inputs14 safe inputs / 3 start inputs
Number of safe semiconductor outputs3
Switching capability per safe outputUB / 500 mA; PNP; short circuit proof
Adjustable delay time0 - 990 sec
Number of auxiliary semiconductor outputs6
Switching capability per auxiliary output1 x UB / 500 mA; 5 x UB / 50 mA; PNP; short circuit proof
Number of pulsed outputs4
Input voltageDC 24 V (+/- 15 %)
PL; Cat.; SILCL (EN ISO 13849-1; IEC 62061; IEC 61508)PL e; Cat. 4; SILCL 3
Dimensions45 x 99 x 118 mm
TALOS ® TB-I14O3 incl. plug-in screw terminals474600
TALOS ® TB-I14O3 incl. plug-in sping-cage terminals475600