Code: ZStop S
Marque: Zander Aachen
ZStop-S |
|
Corresponds to the standards |
EN ISO 13850; IEC 60947-5-5; UL508 |
Approvals |
UL |
Safety Contact Type |
IEC 60947-5-1 Douple Break Type Zb |
Contact material |
silver |
Termination |
Clamp up to 2.5 sq. mm conductors |
Rating |
Uitlization Category: AC15 |
Operational Rating |
AC15 A300 240V. 3A/120V 6A AC |
Thermal Current (Ith) |
10A |
Rated Insulation Voltage (Ui) |
500V |
Withstand Voltage |
2500V |
Short Circuit Overload Protection |
Fuse Exernally 10A (FF) |
Body material |
Plastic (ZStop-S), Stainless steel 316 (ZStop SE, LE,LEL). |
Protection |
IP69K Stainless Steel (NEMA 6), IP67 Plastic |
Temperature range |
-25°C to +80°C |
Mechanical Reliability B10d |
1.5 x 10 (superscript 6) operations at 100mA load |
ISO 13849-1 |
up to PLe depending on system architecture |
EN 62061 |
up to SIL3 depending on system architecture |
EN 62061 |
up to SIL3 depending on system architecture |
Order No. ZStop-S (Plastic) |
941600 |