Measuring range: -0.5 ÷ +3.5 mV/V (optional -3.9 ÷ +3.9 mV/V) |
Input sensitivity: 0.02 µV/count |
Full scale non-Linearity: < 0.01 % full scale |
Gain drift: < 0.001 % full scale/°C |
A/D Converter: 24 bit |
Visible resolution (in divisions): > 60000 |
Decimal figures range: 0 ÷ 3 |
Temperature range: -10 ÷ +40 °C |
Storage temperature: -20 ÷ +50°C |
Filter: 0.1 ÷ 25 Hz |
Logic output: 2 outputs (clean contact) Max 24 Vdc/100 mA cad. |
Logic input: 2 optoisolated 24 Vdc PNP (External voltage) |
Serial port: USB, RS232C o RS422/RS485 with ASCII or Modbus RTU protocols |
Analog optional output: Optoisolated 16 bit, Tension: 0 ÷ 5 or 0 ÷ 10 V (R >10 K Ohm), Current: 0 ÷ 20 o 4 ÷ 20 mA (R < 300 Ohm), Linearity: 0,03 of full scale |
Power supply: 24 Vdc ±15 % - absorbed power 5 W |
Regulatory compliance: EN61326-1, EN55011, EN55014 for EMC; EN61010-1 for electrical security |
Baud rate: 2400, 9600, 19200, 38400, 115200 adjustable |
Transmission distance: 15m (RS232C), 1000m (RS422; RS485) |
Power consumption: 115 / 230 Vdc 50/60 Hz |
Fieldbus: Profibus, Devicenet, Profinet, Ethernet, Ethernet IP |
Trasducer input voltage: 5 V (max 6 load cells 350 Ohm) |