Technical Specifications

Rated load (RL): 125, 250, 500, 750, 1000, 1500, 2000, 3000, 5000 Kg
Combined error: ± 0.02 % RO
Repeatability: ± 0.01 % RO
Creep (20 minutes): ±0.017 % RO
Safe overload: 150 % RL
Ultimate overload: 300 % RL
Clamping force without any load: RL 125 ÷ 2000 kg: 136 Nm; RL 3000÷5000kg: 205 Nm
Material: Nickel steel, stainless steel
Degree of protection: IP67
Accuracy class: 3000 OIML (500÷5000 Kg)
Deflection: 0.33 ÷ 0.89 mm
Compensated Temperature: -10 ÷ +40°C
Temperature range: -18 ÷ +65°C
Temperature effect on zero balance: ±0.018 % RO/10°C
Temperature effect on output: ±0.012% of output/10°C
Rated output RO: 3 mV/V ± 0.25%
Zero balance: ±1 % RO
Insulation resistance: > 1000 M Ohm
Input resistance: 343 ÷ 357 Ohm
Output resistance: 349 ÷ 355 Ohm
Recommended input: 5 ÷ 15 Vdc/Vac

Pavone Datasheets