Pavone BLH Nobel load cell KIM-1

Pavone BLH Nobel load cell KIM-1

Code: KIM-1
Brand: Pavone
Rated load RL: 200 kN
Combined error: ±0.1 % RL
Repeatability: 0.02 % RL
Creep (30 minutes): ±0.03 % RL
Safe overload: 50 % RL
Ultimate overload: 100 % RL
Ultimate sideload: 100 % RL
Degree of protection: IP67
Deflection: 0.1 - 0.3 mm
Temperature range: -40 ÷ +100 °C
Temperature effect on zero balance: ±0,003 % RO/°C
Temperature effect on output: ±0.003 % output/°C
Rated output RO: 2.040 mV/V ±0.25 %
Zero balance: ±2 % RO
Insulation resistance: > 4 G Ohm
Input resistance: 350 ±5 Ohm
Output resistance: 350 ±0.5 Ohm
Recommended input: 5 Vdc/ac
Maximum supply voltage: 18 Vdc/ca
Tolerance of shunt calibration values: ±0.25 %

Pavone Datasheets

Country & Language File Name Download Link
United States (English) Technical_Specifications_Pavone_Systems_dat400_ab4429_77453.pdf Download
United States (English) Technical_Specifications_Pavone_Systems_dat500_4f7480_64370.pdf Download
United States (English) Technical_Specifications_Pavone_Systems_dat-500-analog_efec3b_78468.pdf Download
United States (English) Technical_Specifications_Pavone_Systems_mc302_43103b_19246.pdf Download
United States (English) Technical_Specifications_Pavone_Systems_mct-1303-batch_081be9_91178.pdf Download
United States (English) Technical_Specifications_Pavone_Systems_tester1006_9b8a5a_88792.pdf Download

Request a Quote