Code: PSDA0008
Brand: Pavone
The weight transmitter AT 08 is the ideal product for applications with minimal system tare such as pressure platforms or transducers. The weight transmitter AT 08 is completely custm-made and can be personalized according to customer needs. It is also possible to perform Zero and Full Scale adjustment by means of Dip-switches and multi-turn trimmer. Furthermore, it is possible to adjust the minimum capacity and the maximum capacity of the weighing system (zero and full scale adjustment) via the DIP-Switch and the multi-turn trimmer. The 115 or 230 Vac 50/60 Hz power supply (for DIN rail), the 12 Vdc power supply ± 15% (available bipolar output 0 ÷ 5 Vdc) and analogue filter with response time 0.5 ÷ 25 ms are available as options.
Technical Specifications
Full scale non-Linearity: ±0.02% |
Trasducer input voltage: 10 Vac/120 mA (max 4 beam load by 350 Ohm) |
Temperature range: -10 ÷ +50°C (max umidity 85% without condensation) |
Storage temperature: -20 ÷ +70°C |
Temperature drift analog output: 0.005% FS/°C |
Power supply: 24 Vac/Vcc ±15% |
Regulatory compliance: EN50082-2, EN55011, EN61000 |
Analog output: 0 ÷ 10 Vdc bipolar, 0 ÷ 20 mA or 4÷20 mA |
Dimensions: 78 x 92 x 52 mm |
Maximum input signal: 10 mV - 20 mV - 30 mV |
Power consumption: 5 W |
Number of connectable load cells: up to max 4 load cells |
Rensponse time (of analog filter): 5 ÷ 250 ms. (fixed to 5 ms on output mA) |
Analogic filter: Adjustable by single turn trimmer 270 °C |
Request a Quote