Rated Load (RL): 1, 1.5, 2 t
Combined error: ±0.02 % RL
Repeatability: ±0.015 % RO
Creep (30 minutes): ±0.0170 % of applied load
Ultimate overload: 150 % RL
Visible resolution (in divisions): 3000
Compensated Temperature: -10 ÷ + 40 °C
Temperature range: -30 ÷ +70 °C
Temperature effect on zero balance: ±0.0023 % RO/°C
Temperature effect on output: ±0.0010 % of applied load/°C
Rated output RO: ±0.2 mV/V
Zero balance: ±0.2 mV/V
Insulation resistance: >2000 MOhm
Cable Lenght: 5 m
Impedance: 415 ÷ 15 Ohm
Maximum excitation: 15 Vdc/ac RMS
Excitation recommended: 10 Vdc/ac RMS
Output impedance: 350 ±3 Ohm
Ultimate central overload: 300 % RL
Rated output tolerance: ±0.2 mV/V