Measuring range: –4 ÷ +4 mV/V |
Input sensitivity: 0.02 µV/count |
Full scale non-Linearity: <0.01 % |
Gain drift: < 0.001% FS/°C |
Display: 5 digit, red LED (7 segments), h 7 mm |
A/D Converter: 24 bit |
Internal Resolution: 16.000.000 points |
Trasducer input voltage: 4 V (max 4 cells 350 Ohm) |
Frequency signal acquisition: 4 ÷ 123 Hz |
Visible resolution (in divisions): 60 000 |
Divisions value (adjustable): 0.001 ÷ 50 |
Temperature range: -10 ÷ +50°C (max umidity 85% without condensation) |
Storage temperature: -20 ÷ +60 °C |
Filter: 0.2 ÷ 20 Hz |
Logic output: 2 Solid-state relays, (maximum load 24 Vdc / 100 mA each) |
Logic input: 2 optoisolated 24 Vcc PNP (External voltage) |
Serial port: RS232C half duplex with ASCII or Modbus RTU protocol, RS485 full duplex with ASCII or Modbus RTU protocol |
Analog output Non-Linearity: < 0.03% FS |
Temperature drift analog output: < 0.002% FS |
Power supply: 24 V c.c. ±10% – power 2 W |
Regulatory compliance: EN61000-6-2, EN61000-6-3 for EMC; EN61010-1 for electrical security |
Analog output: 16 Bit optoisolated |
Baud rate: 2400 ÷ 115200 adjustable |
Transmission distance: 15 m |
Analog output current: 0/4÷20mA (R max 300 Ohm) |
Analog output voltage: 0÷5/10V (R min10 K Ohm) |
Solicitar una Cotización