Pavone Tedea load cell 1010/1015

Pavone Tedea load cell 1010/1015

Code: 1010/1015
Marque: Pavone
Rated Load (RL): 3*, 5, 7, 10, 15, 20, 30, 50, 90* kg *no NTEP
Ultimate overload: 300 % RL
Material: Plated (anodize) aluminium
Degree of protection: IP65, IP67
Compensated Temperature: -10 ÷ +40°C
Temperature range: -20 ÷ +70°C
Temperature effect on zero balance: ±0.0023 % (NTEP); ±0.004 % (Non Approved) RO/°C
Temperature effect on output: ±0.001 % (NTEP); ±0.0010 % (Non Approved) RO/°C
Rated output RO: 2 mV/V
Zero balance: ±0.20 mV/V
Insulation resistance: > 5000 MOhm
Input impedance: 415±15 Ohm
Maximum input voltage: 15 Vdc or Vac rms
Nominal input voltage: 10 Vdc or Vac rms
Cable Lenght: 1 m
Load plan: Up to 30kg 40x40; Over 30kg 35x35
Output impedance: 350±3 Ohm

Pavone Fiches techniques